This study compared dimensional accuracy of the single, double with spacer, double with cut-out and double mix impression technique using addition silicone impression material. A typhodont containing Ivorine teeth model with six (6) full-crown tooth preparations were used as the positive control. Two stone replication models for each impression technique were made as test materials. Accuracy of the techniques were assessed by measuring four dimensions on the stone dies poured from the impression of the Ivorine teeth model. Results indicated that most of the measurements for the height, width and diameter slightly decreased and a few increased compared with the Ivorine teeth model. The double with cut-out and double mix technique presents the least difference from the master model as compared to the two latter impression techniques.