Efficacy of a washer-pasteurizer for disinfection of respiratory-care equipment

Infect Control Hosp Epidemiol. 2000 May;21(5):333-6. doi: 10.1086/501767.

Abstract

We evaluated the efficacy of a commercial washer-pasteurizer. Carriers were inoculated with 10(4) to 10(6) test organisms and pasteurized at 170 degrees F for 30 minutes. Pasteurization eliminated all test organisms with the exception of Bacillus subtilis spores. Pasteurization appears efficacious for the disinfection of respiratory-care equipment and could result in a cost savings of approximately $30,000 per year.

MeSH terms

  • Bacillus subtilis / isolation & purification
  • Cost Control
  • Disinfection / economics*
  • Disinfection / instrumentation*
  • Disinfection / methods
  • Equipment Contamination / prevention & control*
  • Evaluation Studies as Topic
  • Metals
  • Plastics
  • Respiratory Therapy / instrumentation*

Substances

  • Metals
  • Plastics