Principles and controversies in lymphoscintigraphy with emphasis on breast cancer

Surg Clin North Am. 2000 Dec;80(6):1721-39. doi: 10.1016/s0039-6109(05)70257-7.

Abstract

The concept of the sentinel node lay fallow until lymph node mapping was developed. This article provides a brief history of the sentinel lymph node concept, discusses reproducibility, radiopharmaceuticals, equipment, techniques, and radiation safety, and addresses metastasis in breast cancer and controversies in breast lymphoscintigraphy.

Publication types

  • Research Support, Non-U.S. Gov't
  • Review

MeSH terms

  • Breast Neoplasms / pathology*
  • Female
  • Gamma Cameras
  • Humans
  • Lymphatic Metastasis / diagnostic imaging*
  • Melanoma / pathology
  • Neoplasm Staging / methods
  • Radiation Protection
  • Radionuclide Imaging / instrumentation
  • Radionuclide Imaging / methods*
  • Radionuclide Imaging / trends
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Rosaniline Dyes
  • Skin Neoplasms / pathology

Substances

  • Radiopharmaceuticals
  • Rosaniline Dyes
  • iso-sulfan blue