Double bag or Y-set versus standard transfer systems for continuous ambulatory peritoneal dialysis in end-stage renal disease

Cochrane Database Syst Rev. 2001:(2):CD003078. doi: 10.1002/14651858.CD003078.

Abstract

Background: Peritonitis is the most frequent serious complication of continuous ambulatory peritoneal dialysis (CAPD). It has a major influence on the number of patients switching from CAPD to haemodialysis and has probably restricted the wider acceptance and uptake of CAPD as an alternative mode of dialysis.

Objectives: This systematic review sought to determine if modifications of the transfer set (Y-set or double bag systems) used in CAPD exchanges are associated with a reduction in peritonitis and an improvement in other relevant outcomes.

Search strategy: A broad search strategy was employed which attempted to identify all RCTs or quasi-RCTs relevant to the management of end-stage renal disease (ESRD). Five electronic databases were searched (Medline 1966-1999, EMBASE 1984-1999, CINAHL 1982-1996, BIOSIS 1985-1996 and the Cochrane Library), authors of included studies and relevant biomedical companies were contacted, reference lists of identified RCTs and relevant narrative reviews were screened and Kidney International 1980-1997 was hand searched.

Selection criteria: Randomised or quasi-randomised controlled trials comparing double bag, Y-set and standard CAPD exchange systems in patients with ESRD.

Data collection and analysis: Data were abstracted by a single investigator onto a standard form and subsequently entered into Review Manager 4.0.4. Odds Ratio (OR) for dichotomous data and a (Weighted) Mean Difference (WMD) for continuous data were calculated with 95% confidence intervals (95% CI).

Main results: Twelve eligible trials with a total of 991 randomised patients were identified. In trials comparing either the Y-set or double bag systems with the standard systems significantly fewer patients (OR 0.33, 95% CI 0.24 to 0.46) experienced peritonitis and the number of patient-months on CAPD per episode of peritonitis were consistently greater. When the double bag systems were compared with the Y-set systems significantly fewer patients experienced peritonitis (OR 0.44, 95% CI 0.27 to 0.71) and the numbers of patient-months on CAPD/ episode of peritonitis were also greater.

Reviewer's conclusions: Double bag systems should be the preferred exchange systems in CAPD.

Publication types

  • Review
  • Systematic Review

MeSH terms

  • Humans
  • Kidney Failure, Chronic / therapy
  • Peritoneal Dialysis, Continuous Ambulatory / adverse effects
  • Peritoneal Dialysis, Continuous Ambulatory / instrumentation
  • Peritoneal Dialysis, Continuous Ambulatory / methods*
  • Peritonitis / etiology
  • Peritonitis / prevention & control*
  • Randomized Controlled Trials as Topic