Performing phacoemulsification during a triple corneal procedure has many advantages. Operating in a closed chamber makes surgery easier and safer. In some cases, however, a dense corneal opacity may prevent closed-chamber surgery, necessitating the use of an open-sky technique. In these cases, a temporary corneal graft using a corneal button not suitable for penetrating keratoplasty is proposed to allow phacoemulsification and foldable intraocular lens implantation through a corneal tunnel. The temporary corneal graft is replaced with a permanent graft after these steps are completed. This technique was effective in 3 patients with cataract and dense corneal opacity.