Screening mammograms by community radiologists: variability in false-positive rates

J Natl Cancer Inst. 2002 Sep 18;94(18):1373-80. doi: 10.1093/jnci/94.18.1373.

Abstract

Background: Previous studies have shown that the agreement among radiologists interpreting a test set of mammograms is relatively low. However, data available from real-world settings are sparse. We studied mammographic examination interpretations by radiologists practicing in a community setting and evaluated whether the variability in false-positive rates could be explained by patient, radiologist, and/or testing characteristics.

Methods: We used medical records on randomly selected women aged 40-69 years who had had at least one screening mammographic examination in a community setting between January 1, 1985, and June 30, 1993. Twenty-four radiologists interpreted 8734 screening mammograms from 2169 women. Hierarchical logistic regression models were used to examine the impact of patient, radiologist, and testing characteristics. All statistical tests were two-sided.

Results: Radiologists varied widely in mammographic examination interpretations, with a mass noted in 0%-7.9%, calcification in 0%-21.3%, and fibrocystic changes in 1.6%-27.8% of mammograms read. False-positive rates ranged from 2.6% to 15.9%. Younger and more recently trained radiologists had higher false-positive rates. Adjustment for patient, radiologist, and testing characteristics narrowed the range of false-positive rates to 3.5%-7.9%. If a woman went to two randomly selected radiologists, her odds, after adjustment, of having a false-positive reading would be 1.5 times greater for the radiologist at higher risk of a false-positive reading, compared with the radiologist at lowest risk (95% highest posterior density interval [similar to a confidence interval] = 1.17 to 2.08).

Conclusion: Community radiologists varied widely in their false-positive rates in screening mammograms; this variability range was reduced by half, but not eliminated, after statistical adjustment for patient, radiologist, and testing characteristics. These characteristics need to be considered when evaluating false-positive rates in community mammographic examination screening.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Adult
  • Aged
  • Breast Diseases / diagnostic imaging
  • Breast Neoplasms / diagnostic imaging*
  • Calcinosis / diagnostic imaging
  • Cohort Studies
  • Diagnosis, Differential
  • False Positive Reactions
  • Female
  • Fibrocystic Breast Disease / diagnostic imaging
  • Humans
  • Mammography / standards*
  • Mass Screening / standards*
  • Middle Aged
  • Models, Statistical
  • Observer Variation
  • Odds Ratio
  • Radiology / standards*
  • Reproducibility of Results