Environmental and occupational health response to SARS, Taiwan, 2003

Emerg Infect Dis. 2004 Jul;10(7):1187-94. doi: 10.3201/eid1007.030728.

Abstract

Industrial hygiene specialists from the National Institute for Occupational Safety and Health (NIOSH) visited hospitals and medical centers throughout Taiwan. They assisted with designing and evaluating ventilation modifications for infection control, developed guidelines for converting hospital rooms into SARS patient isolation rooms, prepared designs for the rapid conversion of a vacated military facility into a SARS screening and observation facility, assessed environmental aspects of dedicated SARS hospitals, and worked in concert with the Taiwanese to develop hospital ventilation guidelines. We describe the environmental findings and observations from this response, including the rapid reconfiguration of medical facilities during a national health emergency, and discuss environmental challenges should SARS or a SARS-like virus emerge again.

MeSH terms

  • Cross Infection / prevention & control*
  • Environmental Monitoring* / methods
  • Environmental Monitoring* / standards
  • Hospitals*
  • Humans
  • Infection Control / methods
  • Infection Control / standards
  • Occupational Health*
  • Patient Isolation
  • Practice Guidelines as Topic
  • Severe Acute Respiratory Syndrome / prevention & control*
  • Taiwan
  • Ventilation / standards