Objective: In patients with uncontrolled systolic hypertension, to estimate the value of home blood pressure monitoring in addition to office blood pressure for inclusion in a trial.
Methods: 80 patients with systolic hypertension, defined as SBP > or =140 mmHg and pulse pressure > or =60 mmHg, were treated for 4 weeks with a thiazide diuretic at usual dose (25 mg HCTZ or 1.5 mg indapamide or methyclothiazide 5 mg). Blood pressure was measured using an automatic monitor (Omron M6) at office and at home in the 3 days prior the visit. Subjects with an uncontrolled hypertension were included in the second part of the trial only if there fulfilled inclusion criteria: office SBP > or =140 mmHg and home SBP > or =135 mmHg (mean of 18 measurements obtained on 3 consecutive days) and office pulse pressure > or =60 mmHg.
Results: After 4 weeks with diuretic treatment, 62% of patients fulfilled 3 criteria and were included in the second part of the trial. It was observed 76% of patients with office SBP > or =140 mmHg, 72% with office pulse pressure > or =60 mmHg and 70% with both office SBP and PP criteria. However, only 67% of patients had home SBP > or =135 mmHg. Discrepancy between office and home SBP was observed and subjects with a white coat hypertension was noticed in 14% and masked hypertension in 5%.
Conclusion: If patients with systolic hypertension have to be included into a drug trial because there are uncontrolled, home blood pressure monitoring in addition to office blood pressure is a very useful criteria for inclusion because misclassifications due to white coat or masked hypertension is frequent in these patients.