Wood cellulose preparation methods and mass spectrometric analyses of delta13C, delta18O, and nonexchangeable delta2H values in cellulose, sugar, and starch: an interlaboratory comparison

Anal Chem. 2007 Jun 15;79(12):4603-12. doi: 10.1021/ac0700023. Epub 2007 May 16.

Abstract

Interlaboratory comparisons involving nine European stable isotope laboratories have shown that the routine methods of cellulose preparation resulted in data that generally agreed within the precision of the isotope ratio mass spectrometry (IRMS) method used: +/-0.2 per thousand for carbon and +/-0.3 per thousand for oxygen. For carbon, the results suggest that holocellulose is enriched up to 0.39 per thousand in 13C relative to the purified alpha-cellulose. The comparisons of IRMS measurements of carbon on cellulose, sugars, and starches showed low deviations from -0.23 to +0.23 per thousand between laboratories. For oxygen, IRMS measurements varied between means from -0.39 to 0.58 per thousand, -0.89 to 0.42 per thousand, and -1.30 to 1.16 per thousand for celluloses, sugars, and starches, respectively. This can be explained by different effects arising from the use of low- or high-temperature pyrolysis and by the variation between laboratories in the procedures used for drying and storage of samples. The results of analyses of nonexchangeable hydrogen are very similar in means with standard deviations between individual methods from +/-2.7 to +/-4.9 per thousand. The use of a one-point calibration (IAEA-CH7) gave significant positive offsets in delta2H values up to 6 per thousand. Detailed analysis of the results allows us to make the following recommendations in order to increase quality and compatibility of the common data bank: (1) removal of a pretreatment with organic solvents, (2) a purification step with 17% sodium hydroxide solution during cellulose preparation procedure, (3) measurements of oxygen isotopes under an argon hood, (4) use of calibration standard materials, which are of similar nature to that of the measured samples, and (5) using a two-point calibration method for reliable result calculation.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Calibration
  • Carbohydrates / analysis*
  • Carbon Isotopes / analysis
  • Cellulose / analysis*
  • Cellulose / chemistry
  • Deuterium / analysis
  • Isotopes / analysis*
  • Mass Spectrometry / methods*
  • Organic Chemicals / chemistry
  • Oxygen Isotopes / analysis
  • Sodium Hydroxide / chemistry
  • Solvents / chemistry
  • Starch / analysis*
  • Temperature
  • Wood*

Substances

  • Carbohydrates
  • Carbon Isotopes
  • Isotopes
  • Organic Chemicals
  • Oxygen Isotopes
  • Solvents
  • Sodium Hydroxide
  • Cellulose
  • Starch
  • Deuterium