Clinical CT-based calculations of dose and positron emitter distributions in proton therapy using the FLUKA Monte Carlo code

Phys Med Biol. 2007 Jun 21;52(12):3369-87. doi: 10.1088/0031-9155/52/12/004. Epub 2007 May 17.

Abstract

Clinical investigations on post-irradiation PET/CT (positron emission tomography/computed tomography) imaging for in vivo verification of treatment delivery and, in particular, beam range in proton therapy are underway at Massachusetts General Hospital (MGH). Within this project, we have developed a Monte Carlo framework for CT-based calculation of dose and irradiation-induced positron emitter distributions. Initial proton beam information is provided by a separate Geant4 Monte Carlo simulation modelling the treatment head. Particle transport in the patient is performed in the CT voxel geometry using the FLUKA Monte Carlo code. The implementation uses a discrete number of different tissue types with composition and mean density deduced from the CT scan. Scaling factors are introduced to account for the continuous Hounsfield unit dependence of the mass density and of the relative stopping power ratio to water used by the treatment planning system (XiO (Computerized Medical Systems Inc.)). Resulting Monte Carlo dose distributions are generally found in good correspondence with calculations of the treatment planning program, except a few cases (e.g. in the presence of air/tissue interfaces). Whereas dose is computed using standard FLUKA utilities, positron emitter distributions are calculated by internally combining proton fluence with experimental and evaluated cross-sections yielding 11C, 15O, 14O, 13N, 38K and 30P. Simulated positron emitter distributions yield PET images in good agreement with measurements. In this paper, we describe in detail the specific implementation of the FLUKA calculation framework, which may be easily adapted to handle arbitrary phase spaces of proton beams delivered by other facilities or include more reaction channels based on additional cross-section data. Further, we demonstrate the effects of different acquisition time regimes (e.g., PET imaging during or after irradiation) on the intensity and spatial distribution of the irradiation-induced beta+-activity signal for the cases of head and neck and para-spinal tumour sites.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Electrons*
  • Humans
  • Monte Carlo Method*
  • Neuroectodermal Tumors / diagnostic imaging
  • Pituitary Neoplasms / diagnostic imaging
  • Positron-Emission Tomography / methods
  • Protons*
  • Radioisotopes / pharmacokinetics
  • Radioisotopes / therapeutic use*
  • Radiotherapy Planning, Computer-Assisted*
  • Tomography, X-Ray Computed / methods

Substances

  • Protons
  • Radioisotopes