External fixation devices in the treatment of fractures of the tibial plafond: a systematic review of the literature

J Bone Joint Surg Br. 2008 Jan;90(1):1-6. doi: 10.1302/0301-620X.90B1.19858.

Abstract

We have compared the outcomes of the use of external fixation devices for spanning or sparing the ankle joint in the treatment of fractures of the tibial plafond, focusing on the complications and the rates of healing. We have devised a scoring system for the quality of reporting of clinical outcomes, to determine the reliability of the results. We conducted a search of publications in English between 1990 and 2006 using the Pubmed search engine. The key words used were pilon, pylon, plafond fractures, external fixation. A total of 15 articles, which included 465 fractures, were eligible for final evaluation. There were no statistically significant differences between spanning and sparing fixation systems regarding the rates of infection, nonunion, and the time to union. Patients treated with spanning frames had significantly greater incidence of malunion compared with patients treated with sparing frames. In both groups, the outcome reporting score was very low; 60% of reports involving infection, nonunion or malunion scored 0 points.

Publication types

  • Review
  • Systematic Review

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Ankle Joint / surgery
  • Bacterial Infections / etiology
  • External Fixators* / adverse effects
  • Female
  • Fracture Fixation / adverse effects
  • Fracture Fixation / instrumentation*
  • Fracture Fixation / methods
  • Fractures, Malunited / etiology
  • Fractures, Ununited / etiology
  • Humans
  • Male
  • Middle Aged
  • Reproducibility of Results
  • Tibial Fractures / complications
  • Tibial Fractures / surgery*
  • Treatment Outcome