Texture analysis in non-contrast enhanced CT: impact of malignancy on texture in apparently disease-free areas of the liver

Eur J Radiol. 2009 Apr;70(1):101-10. doi: 10.1016/j.ejrad.2007.12.005. Epub 2008 Feb 1.

Abstract

Objectives: To determine whether texture analysis of non-contrast enhanced computed tomography (CT) images in apparently disease-free areas of the liver is altered by the presence of extra- and intra-hepatic malignancy in colorectal cancer patients.

Materials and methods: Hepatic attenuation and texture were assessed from non-contrast enhanced CT in three groups of colorectal cancer patients: (A) 15 controls with no malignancy; (B) nine patients with extra-hepatic malignancy but no liver involvement; (C) eight patients with hepatic metastases. Regions of interest were manually constructed only over apparently normal areas of liver tissue excluding major blood vessels and areas of intra-hepatic fat, which may otherwise alter CT texture irrespective of the presence of malignancy. Texture was analysed on unfiltered images and following band-pass image filtration to highlight image features at different spatial frequencies (fine: 2 pixels/1.68 mm in width, medium: 6 pixels/5.04 mm and coarse: 12 pixels/10.08 mm). The relative contributions made to the image by features at two different spatial frequencies were expressed as filter ratios (fine/medium, fine/coarse and medium/coarse). Texture was quantified as mean grey-level intensity, entropy and uniformity.

Results: Texture was not altered on unfiltered images whereas relative texture analysis following image filtration identified differences in fine to medium texture ratios in apparently disease-free areas of the liver in patients with hepatic metastases as compared to patients with no tumour (entropy, p=0.0257) and patients with extra-hepatic disease (uniformity, p=0.0143).

Conclusions: Relative texture analysis of unenhanced hepatic CT can reveal changes in apparently disease-free areas of the liver that have previously required more complex perfusion measurements for detection.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Algorithms*
  • Contrast Media
  • Female
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Liver / diagnostic imaging*
  • Liver Neoplasms / diagnostic imaging*
  • Male
  • Middle Aged
  • Pattern Recognition, Automated / methods*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*

Substances

  • Contrast Media