Magnetic resonance whole body imaging at 3 Tesla: feasibility and findings in a cohort of asymptomatic medical doctors

Hong Kong Med J. 2008 Apr;14(2):90-6.

Abstract

Objectives: To evaluate the feasibility of whole body imaging using a 3 Tesla magnetic resonance scanner without a contrast agent, and to study the prevalence of abnormal findings among a cohort of asymptomatic doctors.

Design: Prospective study.

Setting: Private hospital, Hong Kong.

Participants: A total of 132 asymptomatic medical doctors (111 men, 21 women), with a mean age of 56 (range, 38-82) years, volunteered for the study. They underwent corresponding whole body imaging at our hospital between October 2005 and February 2006. Imaging involved a 3 Tesla magnetic resonance scanner with 32 channels, parallel imaging, Total Imaging Matrix technology, a maximum gradient amplitude of 40 mT/m and a slew rate of 200 mT/m/ms (Magnetom Tim Trio, Siemens Medical Solution, Erlangen, Germany). The use of matrix coils enabled coverage of the whole body. No contrast agent was used.

Main outcome measures: Detection of abnormalities in asymptomatic, apparently healthy adults.

Results: All examinations were completed successfully. The mean scan time per subject was 33 (standard deviation, 4) minutes. All subjects tolerated the examination well and overall imaging quality was satisfactory. A total of 124 (94%) subjects had positive findings, of whom 24 (18%) had further workup. Five (4%) subjects were found to have tumours, of which two (1.5%) were proven malignant. Our cancer detection rate was comparable to that of other reported whole body screening studies using contrast magnetic resonance imaging and positron emission tomography.

Conclusion: We demonstrated the feasibility of performing whole body imaging in 30 minutes, using 32-channel magnetic resonance imaging at 3 Tesla without a contrast agent or any ionising radiation.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Cohort Studies
  • Cross-Sectional Studies
  • Feasibility Studies
  • Female
  • Hong Kong
  • Hospitals, Private
  • Humans
  • Image Processing, Computer-Assisted*
  • Incidental Findings*
  • Magnetic Resonance Imaging*
  • Male
  • Mass Screening / statistics & numerical data
  • Medical Staff, Hospital*
  • Middle Aged
  • Neoplasms / diagnosis*
  • Neoplasms / epidemiology
  • Prospective Studies
  • Reference Values
  • Sensitivity and Specificity
  • Whole Body Imaging*