Renewed endovascular repair for recurrent acute abdominal aortic aneurysm

Emerg Radiol. 2009 May;16(3):239-42. doi: 10.1007/s10140-008-0721-6. Epub 2008 May 15.

Abstract

The aim of the study was to describe the successful endovascular management of a patient who was admitted urgently with a second episode of acute abdominal aortic aneurysm (AAA) 30 months after emergency endovascular abdominal aortic aneurysm repair (eEVAR) for a ruptured AAA. The patient, an 84 year-old male physician, presented with severe acute abdominal and back pain. Contrast-enhanced computer tomography scanning showed type III endoleak owing to complete disconnection of both graft limbs and the prosthetic main body. Treatment consisted of acute stent-grafting with two bridging stent-grafts to seal the endoleak and reline the graft. The patient is alive and well 6 months postoperatively. This case indicates the need for follow-up after eEVAR, but also that complications can be managed endovascularly.

Publication types

  • Case Reports

MeSH terms

  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal / diagnostic imaging*
  • Aortic Aneurysm, Abdominal / surgery*
  • Blood Vessel Prosthesis Implantation / adverse effects*
  • Humans
  • Male
  • Postoperative Complications*
  • Recurrence
  • Tomography, X-Ray Computed