Combined ultrasmall superparamagnetic particles of iron oxide-enhanced and diffusion-weighted magnetic resonance imaging reliably detect pelvic lymph node metastases in normal-sized nodes of bladder and prostate cancer patients

Eur Urol. 2009 Apr;55(4):761-9. doi: 10.1016/j.eururo.2008.12.034. Epub 2009 Jan 7.

Abstract

Background: Lymph node staging of bladder or prostate cancer using conventional imaging is limited. Newer approaches such as ultrasmall superparamagnetic particles of iron oxide (USPIO) and diffusion-weighted magnetic resonance imaging (DW-MRI) have inconsistent diagnostic accuracy and are difficult to interpret.

Objective: To assess whether combined USPIO and DW-MRI (USPIO-DW-MRI) improves staging of normal-sized lymph nodes in bladder and/or prostate cancer patients.

Design, setting, and participants: Twenty-one consecutive patients with bladder and/or prostate cancer were enrolled between May and October 2008. One patient was excluded secondary to bone metastases detected on DW-MRI with subsequent abstention from surgery.

Intervention: Patients preoperatively underwent 3-T MRI before and after administration of lymphotropic USPIO using conventional MRI sequences combined with DW-MRI. Surgery consisted of extended pelvic lymphadenectomy and resection of primary tumors.

Measurements: Diagnostic accuracies of the new combined USPIO-DW-MRI approach compared with the "classic" reading method evaluating USPIO images without and with DW-MRI versus histopathology were evaluated. Duration of the two reading methods was noted for each patient.

Results and limitations: Diagnostic accuracy (90% per patient or per pelvic side) was comparable for the classic and the USPIO-DW-MRI reading method, while time of analysis with 80 min (range 45-180 min) for the classic and 13 min (range 5-90 min) for the USPIO-DW-MRI method was significantly shorter (p<0.0001). Interobserver agreement (three blinded readers) was high with a kappa value of 0.75 and 0.84, respectively. Histopathological analysis showed metastases in 26 of 802 analyzed lymph nodes (3.2%). Of these, 24 nodes (92%) were correctly diagnosed as positive on USPIO-DW-MRI. In two patients, one micrometastasis each (1.0x0.2 mm; 0.7x0.4 mm) was missed in all imaging studies.

Conclusions: USPIO-DW-MRI is a fast and accurate method for detecting pelvic lymph node metastases, even in normal-sized nodes of bladder or prostate cancer patients.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Contrast Media*
  • Dextrans*
  • Diffusion Magnetic Resonance Imaging / methods*
  • Female
  • Ferrosoferric Oxide*
  • Humans
  • Lymphatic Metastasis
  • Magnetite Nanoparticles
  • Male
  • Middle Aged
  • Neoplasm Staging
  • Pilot Projects
  • Prostatic Neoplasms / pathology*
  • Reproducibility of Results
  • Urinary Bladder Neoplasms / pathology*

Substances

  • Contrast Media
  • Dextrans
  • Magnetite Nanoparticles
  • ferumoxtran-10
  • Ferrosoferric Oxide