Symmetry in computed tomography of the brain: the pitfalls

Clin Radiol. 2009 Mar;64(3):298-306. doi: 10.1016/j.crad.2008.08.012. Epub 2008 Nov 6.

Abstract

Computed tomography (CT) studies of the brain are one of the most frequent examinations interpreted by radiologists out of hours. Apparently normal appearances in patients with significant neurological morbidity can be perplexing. As the contents of the cranium are normally remarkably symmetrical on axial CT, disease entities that result in symmetrical appearances are the most difficult to detect. In this review we highlight a spectrum of important acute neurological conditions that result in abnormal but symmetrical appearances on CT.

Publication types

  • Review

MeSH terms

  • Brain / diagnostic imaging*
  • Brain Diseases / diagnostic imaging*
  • CADASIL / diagnostic imaging
  • Child
  • Female
  • Hematoma, Subdural / diagnostic imaging
  • Humans
  • Hydrocephalus / diagnostic imaging
  • Hypoxia-Ischemia, Brain / diagnostic imaging
  • Image Processing, Computer-Assisted / methods*
  • Intracranial Hypertension / diagnostic imaging
  • Intracranial Thrombosis / diagnostic imaging
  • Middle Aged
  • Tomography, X-Ray Computed / methods*