CT- and MRI-based volumetry of resected liver specimen: comparison to intraoperative volume and weight measurements and calculation of conversion factors

Eur J Radiol. 2010 Jul;75(1):e107-11. doi: 10.1016/j.ejrad.2009.09.005. Epub 2009 Sep 25.

Abstract

Objective: To compare virtual volume to intraoperative volume and weight measurements of resected liver specimen and calculate appropriate conversion factors to reach better correlation.

Methods: Preoperative (CT-group, n=30; MRI-group, n=30) and postoperative MRI (n=60) imaging was performed in 60 patients undergoing partial liver resection. Intraoperative volume and weight of the resected liver specimen was measured. Virtual volume measurements were performed by two readers (R1,R2) using dedicated software. Conversion factors were calculated.

Results: Mean intraoperative resection weight/volume: CT: 855 g/852 mL; MRI: 872 g/860 mL. Virtual resection volume: CT: 960 mL(R1), 982 mL(R2); MRI: 1112 mL(R1), 1115 mL(R2). Strong positive correlation for both readers between intraoperative and virtual measurements, mean of both readers: CT: R=0.88(volume), R=0.89(weight); MRI: R=0.95(volume), R=0.92(weight). Conversion factors: 0.85(CT), 0.78(MRI).

Conclusion: CT- or MRI-based volumetry of resected liver specimen is accurate and recommended for preoperative planning. A conversion of the result is necessary to improve intraoperative and virtual measurement correlation. We found 0.85 for CT- and 0.78 for MRI-based volumetry the most appropriate conversion factors.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Algorithms
  • Female
  • Hepatectomy*
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Imaging, Three-Dimensional / methods*
  • Liver / diagnostic imaging
  • Liver / pathology
  • Liver / physiopathology*
  • Liver / surgery*
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Organ Size
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*