Context High on-treatment platelet reactivity is associated with atherothrombotic events following coronary stent implantation. Objective To evaluate the capability of multiple platelet function tests to predict clinical outcome. Design, Setting, and Patients Prospective, observational, single-center cohort study of 1069 consecutive patients taking clopidogrel undergoing elective coronary stent implantation between December 2005 and December 2007. On-treatment platelet reactivity was measured in parallel by light transmittance aggregometry, Verify Now P2Y12 and Platelet works assays, and the IMPACT-R and the platelet function analysis system (PFA-100) (with the Dade PFA collagen/adenosine diphosphate (ADP) cartridge and Innovance PFA P2Y). Cutoff values for high on-treatment platelet reactivity were established by receiver operating characteristic curve (ROC) analysis. Main Outcome Measurement The primary end point was defined as a composite of all-cause death, nonfatal acute myocardial infarction, stent thrombosis, and ischemic stroke. The primary safety end point included TIMI (Thrombolysis In Myocardial Infarction) criteria major and minor bleeding. Results Kaplan-Meier analysis demonstrated that at 1-year follow-up, the primary end point occurred more frequently in patients with high on-treatment platelet reactivity when assessed by light transmittance aggregometry (52 [11.7%; 95% confidence interval {CI}, 8.9%-15.0%] vs 36 [6.0%;95%CI, 4.2%-8.2%] P.001; n=1049),Verify Now (54 [13.3%; 95% CI, 10.2%-17.0%] vs 37 [5.7%; 95% CI, 4.1%-7.8%]P.001; n=1052), Platelet works (33 [12.6%; 95% CI, 8.8%-17.2%] vs 21 [6.1%;95% CI, 3.8%-9.2%] P=.005; n=606), and Innovance PFA P2Y (18 [12.2%; 95%CI; 7.4%-18.6%] vs 28 [6.3%; 95% CI, 4.3%-8.9%] P=.02; n=588). ROC-curve analysis demonstrated that light transmittance aggregometry (area under the curve[AUC], 0.63; 95% CI, 0.58-0.68), Verify Now (AUC, 0.62; 95% CI, 0.57-0.67), and Platelet works (AUC, 0.61; 95% CI, 0.53-0.69) had modest ability to discriminate between patients with and without primary end point at 1-year follow-up. The IMPACT-R(n=905) and the Siemens PFA Collagen/ADP (n=812) were unable to discriminate between patients with and without the primary end point at 1-year follow-up (all AUCs included 0.50 in the CI). None of the tests identified patients at risk for bleeding. Conclusions Of the platelet function tests assessed, light transmittance aggregometry,Verify Now, Platelet works, and Innovance PFA P2Y were significantly associated with the primary end point. However, the predictive accuracy of these 4 tests was only modest. None of the tests provided accurate prognostic information to identify patients at higher risk of bleeding following stent implantation. Trial Registration clinical trials.gov Identifier: NCT00352014 [corrected].