Long-term safety and effectiveness of drug-eluting stents for the treatment of saphenous vein grafts disease: a population-based study

JACC Cardiovasc Interv. 2011 Sep;4(9):965-73. doi: 10.1016/j.jcin.2011.06.009.

Abstract

Objectives: The purpose of this study was to evaluate the long-term safety and effectiveness of drug-eluting stents (DES) for the treatment of saphenous vein graft (SVG) disease.

Background: DES are frequently implanted for SVG interventions, but some studies have shown that they are not effective in reducing target vessel revascularization (TVR) over longer-term follow-up. Some studies suggest there is increased mortality with DES compared with bare-metal stents (BMS).

Methods: We performed propensity score matching analysis using a population-based cohort that included 709 well-matched pairs (n = 1,418) who received DES or BMS for the treatment of SVG disease from 2003 to 2008. Outcomes of interest included repeat TVR, myocardial infarction, and death.

Results: The mean age of the propensity-matched cohort was 69 years, 50% had diabetes, and the mean age of SVG was 10.6 years. At 4-year follow-up, the rate of repeat TVR was 21% in the DES group and 27.6% in the BMS group (p = 0.004). DES implantation was associated with the largest TVR reduction among patients with diabetes and patients receiving longer stents (≥30 mm) and the number of procedures needed to prevent a TVR at 4 years was 8 and 7, respectively. The composite rate of myocardial infarction or death was not significantly different between DES and BMS at 4 years (27.8% vs. 32.6%, p = 0.09).

Conclusions: Implantation of DES in the treatment of SVG disease is associated with substantial reduction of repeat revascularization, without evidence of an increased risk of myocardial infarction or death at longer-term follow-up.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Angioplasty, Balloon, Coronary / adverse effects
  • Angioplasty, Balloon, Coronary / instrumentation*
  • Angioplasty, Balloon, Coronary / mortality
  • Coronary Artery Bypass / adverse effects*
  • Drug-Eluting Stents*
  • Female
  • Graft Occlusion, Vascular / etiology
  • Graft Occlusion, Vascular / mortality
  • Graft Occlusion, Vascular / therapy*
  • Humans
  • Kaplan-Meier Estimate
  • Logistic Models
  • Male
  • Metals*
  • Middle Aged
  • Myocardial Infarction / etiology
  • Ontario
  • Propensity Score
  • Proportional Hazards Models
  • Prosthesis Design
  • Registries
  • Risk Assessment
  • Risk Factors
  • Saphenous Vein / transplantation*
  • Stents*
  • Time Factors
  • Treatment Outcome

Substances

  • Metals