Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve

JACC Cardiovasc Interv. 2012 May;5(5):499-512. doi: 10.1016/j.jcin.2012.02.010.

Abstract

Objectives: This study sought to evaluate the predictive factors, effects, and safety of balloon post-dilation (BPD) for the treatment of significant paravalvular aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI).

Background: Very few data exist on BPD after TAVI with a balloon-expandable valve.

Methods: A total of 211 patients who underwent TAVI with a balloon-expandable valve were included. BPD was performed after TAVI if paravalvular AR ≥ 2 was identified by transesophageal echocardiography. Clinical events and echocardiographic data were prospectively recorded, and median follow-up was 12 (6 to 24) months.

Results: BPD was performed in 59 patients (28%), leading to a reduction in at least 1 degree of AR in 71% of patients, with residual AR <2 in 54% of the patients. The predictors of the need for BPD were the degree of valve calcification and transfemoral approach, with valve calcification volume >2,200 and >3,800 mm(3) best determining the need for and a poor response to BPD, respectively. Patients who underwent BPD had a higher incidence of cerebrovascular events at 30 days (11.9% vs. 2.0%, p = 0.006), with most (83%) events within the 24 h after the procedure occurring in patients who had BPD. No significant changes in valve area or AR degree were observed at follow-up in BPD and no-BPD groups.

Conclusions: BPD was needed in about one-fourth of the patients undergoing TAVI with a balloon-expandable valve and was successful in about one-half of them. A higher degree of valve calcification and transfemoral approach predicted the need for BPD. BPD was not associated with any deleterious effect on valve function at mid-term follow-up, but a higher rate of cerebrovascular events was observed in patients who had BPD.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Insufficiency / diagnosis
  • Aortic Valve Insufficiency / etiology
  • Aortic Valve Insufficiency / therapy*
  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / therapy*
  • Calcinosis / complications
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation*
  • Catheterization* / adverse effects
  • Cerebrovascular Disorders / etiology
  • Chi-Square Distribution
  • Echocardiography, Doppler, Color
  • Echocardiography, Transesophageal
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis*
  • Humans
  • Kaplan-Meier Estimate
  • Logistic Models
  • Male
  • Predictive Value of Tests
  • Prospective Studies
  • Prosthesis Design
  • Quebec
  • Risk Assessment
  • Risk Factors
  • Severity of Illness Index
  • Time Factors
  • Tomography, X-Ray Computed
  • Treatment Outcome