Normal liver tissue density dose response in patients treated with stereotactic body radiation therapy for liver metastases

Int J Radiat Oncol Biol Phys. 2012 Nov 1;84(3):e441-6. doi: 10.1016/j.ijrobp.2012.04.041. Epub 2012 Jun 9.

Abstract

Purpose: To evaluate the temporal dose response of normal liver tissue for patients with liver metastases treated with stereotactic body radiation therapy (SBRT).

Methods and materials: Ninety-nine noncontrast follow-up computed tomography (CT) scans of 34 patients who received SBRT between 2004 and 2011 were retrospectively analyzed at a median of 8 months post-SBRT (range, 0.7-36 months). SBRT-induced normal liver tissue density changes in follow-up CT scans were evaluated at 2, 6, 10, 15, and 27 months. The dose distributions from planning CTs were mapped to follow-up CTs to relate the mean Hounsfield unit change (ΔHU) to dose received over the range 0-55 Gy in 3-5 fractions. An absolute density change of 7 HU was considered a significant radiographic change in normal liver tissue.

Results: Increasing radiation dose was linearly correlated with lower post-SBRT liver tissue density (slope, -0.65 ΔHU/5 Gy). The threshold for significant change (-7 ΔHU) was observed in the range of 30-35 Gy. This effect did not vary significantly over the time intervals evaluated.

Conclusions: SBRT induces a dose-dependent and relatively time-independent hypodense radiation reaction within normal liver tissue that is characterized by a decrease of >7 HU in liver density for doses >30-35 Gy.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Dose-Response Relationship, Radiation
  • Female
  • Humans
  • Liver / anatomy & histology*
  • Liver / diagnostic imaging
  • Liver / radiation effects*
  • Liver Neoplasms / pathology
  • Liver Neoplasms / secondary
  • Liver Neoplasms / surgery*
  • Male
  • Middle Aged
  • Radiosurgery / methods*
  • Radiotherapy Dosage
  • Radiotherapy, Conformal / methods
  • Retrospective Studies
  • Time Factors
  • Tomography, X-Ray Computed