Radiochromic films for dental CT dosimetry: a feasibility study

Phys Med. 2014 Feb;30(1):18-24. doi: 10.1016/j.ejmp.2012.06.002. Epub 2012 Jun 30.

Abstract

Dental CT dose evaluations are commonly performed using thermoluminescent dosimeters (TLD) inside anthropomorphic phantoms. Radiochromic films with good sensitivity in the X-ray diagnostic field have recently been developed and are commercially available as GAFCHROMIC XR-QA. There are potential advantages in the use of radiochromic films such as a more comprehensive dosimetry thanks to the adjustable size of the film samples. The purpose of this study was to investigate the feasibility of using radiochromic films for dental CT dose evaluations. Film samples were cut with a width of 5mm and a length of 25 mm (strips), the same size as the Alderson Rando anthropomorphic phantom holes used in this study. Dental CT dose measurements were performed using simultaneously both TLD and radiochromic strips in the same phantom sites. Two equipment types were considered for dental CT examinations: a 16 slice CT and a cone beam CT. Organ equivalent doses were then obtained averaging the measurements from the sites of the same organ and effective doses were calculated using ICRP 103 weighting factors. The entire procedure was repeated four times for each CT in order to compare also the repeatability of the two dosimeter types. A linear correlation was found between the absorbed dose evaluated with radiochromic films and with TLD, with slopes of 0.930 and 0.944 (correlation r>0.99). The maximum difference between the two dosimeter's measurements was 25%, whereas the average difference was 7%. The measurement repeatability was comparable for the two dosimeters at cumulative doses above 15 mGy (estimated uncertainty at 1 sigma level of about 5%), whereas below this threshold radiochromic films show a greater dispersion of data, of about 10% at 1 sigma level. We obtained, using respectively Gafchromic and TLD measurements, effective dose values of 107 μSv and 117 μSv (i.e. difference of 8.6%) for the cone beam CT and of 523 μSv and 562 μSv (i.e. difference of 7%) for the multislice CT. This study demonstrates the feasibility of radiochromic films for dental CT dosimetry, pointing out a good agreement with the results obtained using TLD, with potential advantages and the chance of a more extensive dose investigation.

Keywords: Cone beam CT; Dentomaxillofacial; Multislice CT; Patient dose; Radiochromic film.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Dentistry*
  • Feasibility Studies
  • Film Dosimetry / methods*
  • Humans
  • Phantoms, Imaging
  • Radiation Dosage
  • Tomography, X-Ray Computed*