Right subclavian approach as a feasible alternative for transcatheter aortic valve implantation with the CoreValve ReValving System

EuroIntervention. 2012 Oct;8(6):685-90. doi: 10.4244/EIJV8I6A107.

Abstract

Aims: Arterial access selection is crucial during transcatheter aortic valve implantation. When traditional femoral access has been deemed unfeasible the left subclavian artery has been used successfully. In cases where even the latter was ineligible, we opted, despite the lack of any data, for the right subclavian approach. We hereby present the results of the first series available. Our aim was to evaluate the feasibility and performance of the CoreValve ReValving System (CRS) implantation via the right subclavian artery in patients with contraindication to femoral and left subclavian accesses.

Methods and results: Among 300 patients who have undergone CRS implantation, 70 (23%) have been treated via the subclavian approach, 10 via the right subclavian artery and 60 via the left. Demographic features were quite similar except for the presence of significant left subclavian disease in all patients treated via the right subclavian artery. The success rate was 100% for both groups. At 30-day follow-up, there was no significant difference in terms of all-cause mortality and cardiac mortality between right vs. left subclavian approach (0% vs. 6.6% and 0% vs. 6.6%, respectively). Consistent results were observed at a mean follow-up of 12±7.9 months (all-cause mortality: 10% vs. 15%). Incidences of new AV block requiring PM implantation were also statistically equivalent.

Conclusions: CRS implantation via the right subclavian artery was as feasible and safe as the left subclavian approach. It poses very particular technical issues but should be considered when more conventional approaches are inadequate in order to provide patients with a further chance to be treated effectively.

Publication types

  • Multicenter Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve* / diagnostic imaging
  • Bioprosthesis*
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation*
  • Cardiac Catheterization / mortality
  • Chi-Square Distribution
  • Feasibility Studies
  • Female
  • Femoral Artery
  • Heart Valve Diseases / diagnostic imaging
  • Heart Valve Diseases / mortality
  • Heart Valve Diseases / therapy*
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Humans
  • Italy
  • Male
  • Prosthesis Design
  • Radiography, Interventional
  • Retrospective Studies
  • Subclavian Artery* / diagnostic imaging
  • Time Factors
  • Treatment Outcome