Voxel-based Relaxometry of transverse relaxation rate with gradient echo R2(*) in patients with multiple system atrophy

Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2012 Oct;34(5):450-4. doi: 10.3881/j.issn.1000-503X.2012.05.003.

Abstract

Objective: To explore the transverse relaxation rate with gradient echo R2(*) changes in patients with Parkinsonian variant of multiple system atrophy (MSA-P) with a voxel-based analysis of R2(*) map.

Methods: Whole brain structural images and multi-echo T2(*) weighted image were acquired in 27 patients with probable MSA-P and 24 healthy individuals. R2(*) maps of the MSA-P were compared with the controls by voxel-based methods.

Result: Compared with the controls, MSA-P patients showed significant R2(*) decrease bilaterally in brain stem, cerebellar hemispheres, insular lobe, temporal lobes, caudate nucleus, and corpus callosum (P<0.005).

Conclusions: R2(*) can reveal the significant brain involvements of MSA-P. The introduction of gradient echo may increase the sensitivity, although the susceptible artifact may interfere the detection efficiency of R2(*).