Abstract

Background: Implantation of implantable cardioverter defibrillator for prevention of sudden cardiac death is deferred for 90 days after coronary revascularization, but mortality may be highest early after cardiac procedures in patients with ventricular dysfunction. We determined mortality risk in postrevascularization patients with left ventricular ejection fraction ≤35% and compared survival with those discharged with a wearable cardioverter defibrillator (WCD).

Methods and results: Hospital survivors after surgical (coronary artery bypass graft surgery) or percutaneous (percutaneous coronary intervention [PCI]) revascularization with left ventricular ejection fraction ≤35% were included from Cleveland Clinic and national WCD registries. Kaplan-Meier, Cox proportional hazards, propensity score-matched survival, and hazard function analyses were performed. Early mortality hazard was higher among 4149 patients discharged without a defibrillator compared with 809 with WCDs (90-day mortality post-coronary artery bypass graft surgery 7% versus 3%, P=0.03; post-PCI 10% versus 2%, P<0.0001). WCD use was associated with adjusted lower risks of long-term mortality in the total cohort (39%, P<0.0001) and both post-coronary artery bypass graft surgery (38%, P=0.048) and post-PCI (57%, P<0.0001) cohorts (mean follow-up, 3.2 years). In propensity-matched analyses, WCD use remained associated with lower mortality (58% post-coronary artery bypass graft surgery, P=0.002; 67% post-PCI, P<0.0001). Mortality differences were not attributable solely to therapies for ventricular arrhythmia. Only 1.3% of the WCD group had a documented appropriate therapy.

Conclusions: Patients with left ventricular ejection fraction ≤35% have higher early compared to late mortality after coronary revascularization, particularly after PCI. As early hazard seemed less marked in WCD users, prospective studies in this high-risk population are indicated to confirm whether WCD use as a bridge to left ventricular ejection fraction improvement or implantable cardioverter defibrillator implantation can improve outcomes after coronary revascularization.

Publication types

  • Comparative Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Aged
  • Chi-Square Distribution
  • Coronary Artery Bypass / adverse effects
  • Coronary Artery Bypass / mortality*
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / physiopathology
  • Coronary Artery Disease / surgery
  • Coronary Artery Disease / therapy*
  • Death, Sudden, Cardiac / etiology
  • Death, Sudden, Cardiac / prevention & control*
  • Defibrillators*
  • Electric Countershock / instrumentation*
  • Equipment Design
  • Female
  • Humans
  • Kaplan-Meier Estimate
  • Logistic Models
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / mortality*
  • Propensity Score
  • Proportional Hazards Models
  • Registries
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Stroke Volume
  • Time Factors
  • Treatment Outcome
  • United States / epidemiology
  • Ventricular Dysfunction, Left / mortality*
  • Ventricular Dysfunction, Left / physiopathology
  • Ventricular Function, Left*