Validation of admittance computed left ventricular volumes against real-time three-dimensional echocardiography in the porcine heart

Exp Physiol. 2013 Jun;98(6):1092-101. doi: 10.1113/expphysiol.2012.070821. Epub 2013 Feb 22.

Abstract

The admittance and Wei's equation is a new technique for ventricular volumetry to determine pressure-volume relations that addresses traditional conductance-related issues of parallel conductance and field correction factor. These issues with conductance have prevented researchers from obtaining real-time absolute ventricular volumes. Moreover, the time-consuming steps involved in processing conductance catheter data warrant the need for a better catheter-based technique for ventricular volumetry. We aimed to compare the accuracy of left ventricular (LV) volumetry between the new admittance catheterization technique and transoesophageal real-time three-dimensional echocardiography (RT3DE) in a large-animal model. Eight anaesthetized pigs were used. A 7 French admittance catheter was positioned in the LV via the right carotid artery. The catheter was connected to an admittance control unit (ADVantage; Transonic Scisense Inc.), and data were recorded on a four-channel acquisition system (FA404; iWorx Systems). Admittance catheterization data and transoesophageal RT3DE (X7-2; Philips) data were simultaneously obtained with the animal ventilated, under neuromuscular blockade and monitored in baseline conditions and during dobutamine infusion. Left ventricular volumes measured from admittance catheterization (Labscribe; iWorx Systems) and RT3DE (Qlab; Philips) were compared. In a subset of four animals, admittance volumes were compared with those obtained from traditional conductance catheterization (MPVS Ultra; Millar Instruments). Of 37 sets of measurements compared, admittance- and RT3DE-derived LV volumes and ejection fractions at baseline and in the presence of dobutamine exhibited general agreement, with mean percentage intermethod differences of 10% for end-diastolic volumes, 14% for end-systolic volumes and 9% for ejection fraction; the respective intermethod differences between admittance and conductance in eight data sets compared were 11, 11 and 12%. Admittance volumes were generally higher than those obtained by RT3DE, especially among the larger ventricles. It is concluded that it is feasible to derive pressure-volume relations using admittance catheterization in large animals. This study demonstrated agreements between admittance and RT3DE to within 10-14% mean intermethod difference in the estimation of LV volumes. Further investigation will be required to examine the accuracy of volumes in largest ventricles, where intermethod divergence is greatest.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Cardiac Volume / drug effects
  • Cardiac Volume / physiology*
  • Carotid Arteries / drug effects
  • Carotid Arteries / physiology
  • Catheterization / methods*
  • Catheters
  • Dobutamine / pharmacology
  • Echocardiography, Three-Dimensional / methods*
  • Heart / drug effects
  • Heart / physiopathology*
  • Heart Ventricles / drug effects
  • Heart Ventricles / physiopathology
  • Swine
  • Ventricular Function, Left / drug effects
  • Ventricular Function, Left / physiology*

Substances

  • Dobutamine