High spatial and temporal resolution dynamic contrast-enhanced magnetic resonance angiography using compressed sensing with magnitude image subtraction

Magn Reson Med. 2014 May;71(5):1771-83. doi: 10.1002/mrm.24842. Epub 2013 Jun 25.

Abstract

Purpose: We propose a compressed-sensing (CS) technique based on magnitude image subtraction for high spatial and temporal resolution dynamic contrast-enhanced MR angiography (CE-MRA).

Methods: Our technique integrates the magnitude difference image into the CS reconstruction to promote subtraction sparsity. Fully sampled Cartesian 3D CE-MRA datasets from 6 volunteers were retrospectively under-sampled and three reconstruction strategies were evaluated: k-space subtraction CS, independent CS, and magnitude subtraction CS. The techniques were compared in image quality (vessel delineation, image artifacts, and noise) and image reconstruction error. Our CS technique was further tested on seven volunteers using a prospectively under-sampled CE-MRA sequence.

Results: Compared with k-space subtraction and independent CS, our magnitude subtraction CS provides significantly better vessel delineation and less noise at 4× acceleration, and significantly less reconstruction error at 4× and 8× (P < 0.05 for all). On a 1-4 point image quality scale in vessel delineation, our technique scored 3.8 ± 0.4 at 4×, 2.8 ± 0.4 at 8×, and 2.3 ± 0.6 at 12× acceleration. Using our CS sequence at 12× acceleration, we were able to acquire dynamic CE-MRA with higher spatial and temporal resolution than current clinical TWIST protocol while maintaining comparable image quality (2.8 ± 0.5 vs. 3.0 ± 0.4, P = NS).

Conclusion: Our technique is promising for dynamic CE-MRA.

Keywords: DCE-MRI; background suppression; compressed sensing; dynamic contrast-enhanced MRI; magnetic resonance angiography.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms
  • Arteries / anatomy & histology
  • Arteries / physiology*
  • Blood Flow Velocity / physiology
  • Contrast Media
  • Data Compression / methods*
  • Gadolinium*
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Imaging, Three-Dimensional / methods*
  • Magnetic Resonance Angiography / methods*
  • Organometallic Compounds*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Subtraction Technique*

Substances

  • Contrast Media
  • Organometallic Compounds
  • Gadolinium
  • gadofosveset trisodium