Assessing intrarenal nonperfusion and vascular leakage in acute kidney injury with multinuclear (1) H/(19) F MRI and perfluorocarbon nanoparticles

Magn Reson Med. 2014 Jun;71(6):2186-96. doi: 10.1002/mrm.24851. Epub 2013 Aug 8.

Abstract

Purpose: We sought to develop a unique sensor-reporter approach for functional kidney imaging that employs circulating perfluorocarbon nanoparticles and multinuclear (1) H/(19) F MRI.

Methods: (19) F spin density weighted and T1 weighted images were used to generate quantitative functional mappings of both healthy and ischemia-reperfusion (acute kidney injury) injured mouse kidneys. (1) H blood-oxygenation-level-dependent (BOLD) MRI was also employed as a supplementary approach to facilitate the comprehensive analysis of renal circulation and its pathological changes in acute kidney injury.

Results: Heterogeneous blood volume distributions and intrarenal oxygenation gradients were confirmed in healthy kidneys by (19) F MRI. In a mouse model of acute kidney injury, (19) F MRI, in conjunction with blood-oxygenation-level-dependent MRI, sensitively delineated renal vascular damage and recovery. In the cortico-medullary junction region, we observed 25% lower (19) F signal (P < 0.05) and 70% longer (1) H T2* (P < 0.01) in injured kidneys compared with contralateral kidneys at 24 h after initial ischemia-reperfusion injury. We also detected 71% higher (19) F signal (P < 0.01) and 40% lower (1) H T2* (P < 0.05) in the renal medulla region of injured kidneys compared with contralateral uninjured kidneys.

Conclusion: Integrated (1) H/(19) F MRI using perfluorocarbon nanoparticles provides a multiparametric readout of regional perfusion defects in acutely injured kidneys.

Keywords: blood volume; fluorine; ischemia-reperfusion; kidney; oxygenation; perfusion.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acute Kidney Injury / pathology*
  • Animals
  • Blood Volume
  • Calibration
  • Fluorine
  • Fluorocarbons / chemical synthesis
  • Kidney / blood supply*
  • Magnetic Resonance Imaging / methods*
  • Mice
  • Mice, Inbred C57BL
  • Nanoparticles
  • Oxygen / blood*
  • Phantoms, Imaging
  • Reperfusion Injury / pathology*

Substances

  • Fluorocarbons
  • Fluorine
  • Oxygen