Purpose: The present study was performed to analyze the midterm results (five consecutive patients, 2-year follow-up) of the endovascular management of visceral artery aneurysms using the Cardiatis Multilayer Flow Modulator (CMFM) (Cardiatis, Isnes, Belgium), a self-expandable stent.
Materials and methods: From August 2009 to January 2011, we implanted five CMFMs in five patients (all men; mean age 73 years) to treat two common hepatic artery aneurysms, one celiac trunk aneurysm, one splenic artery aneurysm, and one superior mesenteric artery aneurysm (diameter 25-81 mm). The primary end point was technical success. The secondary end point was stent patency, absence of aneurysm rupture or reperfusion, and shrinking of the sac at 6-, 12-, and 24-month follow-up using computed tomography angiography. Follow-up ranged from 24 to 48 months (mean 31.2).
Results: Technical success was achieved in all patients. Complete exclusion of the aneurysm with sac shrinking was achieved in two patients. Two stents became occluded at 6- and 24-month follow-up, respectively; both patients were asymptomatic and were not retreated. One patient developed sac reperfusion due to incomplete aneurysm exclusion.
Conclusion: Long-term results in a wider population are needed to validate the effectiveness of the CMFM.