Angiographic and clinical comparison of novel Orsiro Hybrid sirolimus-eluting stents and Resolute Integrity zotarolimus-eluting stents in all-comers with coronary artery disease (ORIENT trial): study protocol for a randomized controlled trial

Trials. 2013 Nov 20:14:398. doi: 10.1186/1745-6215-14-398.

Abstract

Background: The Orsiro Hybrid sirolimus-eluting stent is a newly developed third-generation drug-eluting stent, featuring a unique dual-polymer mix. An active bioabsorbable polymer delivers the anti-proliferative drug, sirolimus, via controlled release, while a passive biocompatible polymeric coating shields the metallic strut from surrounding tissue, preventing interaction. To date, the Orsiro Hybrid sirolimus-eluting stent has excelled in terms of late lumen loss at 9 months in a first-in-man single-arm trial. However, the efficacy and safety data for Orsiro Hybrid sirolimus-eluting stents in a broader population of all-comers are limited. The present study offers an angiographic and clinical comparison of the Orsiro Hybrid sirolimus-eluting stent and the Resolute Integrity zotarolimus-eluting stent in the treatment of patients with coronary artery disease.

Methods/design: The ORIENT trial is a multicenter, randomized, open-label, parallel-arm study designed to demonstrate the non-inferiority of the Orsiro Hybrid sirolimus-eluting stent relative to the Resolute Integrity zotarolimus-eluting stent. A total of 375 patients with a spectrum of coronary artery disease will undergo prospective, random assignment to a Orsiro Hybrid sirolimus-eluting stent or Resolute Integrity zotarolimus-eluting stent (2:1 ratio), for a primary endpoint of in-stent late lumen loss at 9 months by quantitative coronary angiography. Secondary 12-month clinical endpoints are death, target lesion revascularization, target vessel revascularization, myocardial infarction, stent thrombosis and target lesion failure (a composite of cardiac death, target lesion revascularization and target vessel-related myocardial infarction).

Discussion: The ORIENT trial is the first study to date comparing the Orsiro Hybrid sirolimus-eluting stent with the Resolute Integrity zotarolimus-eluting stent for efficacy and safety in a population of all-comers with coronary artery disease.

Trial registration: Clinicaltrials.gov NCT01826552.

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cardiovascular Agents / administration & dosage*
  • Clinical Protocols
  • Coronary Angiography
  • Coronary Artery Disease / diagnosis
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / therapy*
  • Coronary Restenosis / etiology
  • Coronary Thrombosis / etiology
  • Drug-Eluting Stents*
  • Humans
  • Myocardial Infarction / etiology
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Percutaneous Coronary Intervention / mortality
  • Prospective Studies
  • Prosthesis Design
  • Republic of Korea
  • Research Design*
  • Sirolimus / administration & dosage
  • Sirolimus / analogs & derivatives*
  • Time Factors
  • Treatment Outcome

Substances

  • Cardiovascular Agents
  • zotarolimus
  • Sirolimus

Associated data

  • ClinicalTrials.gov/NCT01826552