Transapical versus transfemoral aortic valve implantation: a multicenter collaborative study

Ann Thorac Surg. 2014 Jan;97(1):22-8. doi: 10.1016/j.athoracsur.2013.09.088. Epub 2013 Nov 19.

Abstract

Background: There are no direct comparisons between transapical aortic valve implantation (TA-AVI) and transfemoral aortic valve implantation (TF-AVI). Therefore, the aim of this study was to compare the short-term and midterm outcomes of TA-AVI versus TF-AVI.

Methods: Data from four European centers were pooled and analyzed. To minimize differences between TA-AVI and TF-AVI multivariable analysis was used. Study endpoints were defined according to the Valve Academic Research Consortium-I criteria at 30 days and 1 year. Primary endpoints of this study were 30-day all-cause mortality and mortality during follow-up.

Results: A total of 882 patients underwent TAVI, of whom 793 (89.9%) underwent TF-AVI and 89 (10.1%) underwent TA-AVI. Patients undergoing TA-AVI had a higher estimated risk of mortality as defined by the logistic European System for Cardiac Operative Risk Evaluation score (median 27.0, interquartile range [IQR]: 20.2 to 33.8 versus median 20.0, IQR: 12.3 to 27.7; p < 0.001) and The Society of Thoracic Surgeons Score (median 10.2, IQR: 5.3 to 9.9 versus median 6.7, IQR: 3.5 to 9.9; p < 0.001) and had more comorbidities. At 30 days, there was an increased risk of all-cause mortality in the TA-AVI group (odds ratio [OR] 3.12, 95% confidence interval [CI]: 1.43 to 6.82; p = 0.004). TF-AVI was associated with a higher frequency of major (OR 0.33, 95% CI: 0.12 to 0.90; p = 0.031) and minor vascular complications (OR 0.17, 95% CI: 0.04 to 0.71; p = 0.0015). In-hospital stay was significantly longer among patients undergoing TA-AVI (OR 2.29, 95% CI: 1.28 to 4.09; p = 0.05). During a median follow-up of 365 days (IQR: 174 to 557), TA-AVI was associated with an increased risk of all-cause mortality (hazard ratio 1.88, 95% CI: 1.23 to 2.87; p = 0.004).

Conclusions: In institutions performing a low volume of TA-AVI, the technique is associated with an increased risk of all-cause mortality and longer hospital stay but less vascular complications in comparison with TF-AVI. The interaction between experience and type of treatment on outcome requires further investigation before advocating one treatment over the other.

Keywords: 35; CI; ESV; Edwards SAPIEN valve; IQR; MCS; Medtronic CoreValve system; OR; STS; TA-AVI; TAVI; TF-AVI; The Society of Thoracic Surgeons; VARC; Valve Academic Research Consortium; confidence interval; interquartile range; odds ratio; transapical aortic valve implantation; transcatheter aortic valve implantation; transfemoral aortic valve implantation.

Publication types

  • Comparative Study
  • Multicenter Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / surgery*
  • Cardiac Catheterization / methods
  • Cohort Studies
  • Confidence Intervals
  • Diagnostic Imaging / methods*
  • Education, Medical, Continuing
  • Endovascular Procedures / methods*
  • Endovascular Procedures / mortality
  • Europe
  • Female
  • Femoral Vein
  • Follow-Up Studies
  • Heart Valve Prosthesis
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Valve Prosthesis Implantation / mortality*
  • Hospital Mortality
  • Humans
  • Kaplan-Meier Estimate
  • Length of Stay
  • Logistic Models
  • Male
  • Multivariate Analysis
  • Odds Ratio
  • Patient Safety
  • Proportional Hazards Models
  • Retrospective Studies
  • Risk Assessment
  • Severity of Illness Index
  • Survival Rate
  • Treatment Outcome