Vessel rejection secondary to human leucocyte antigen antibodies directed against the arterial conduit following pancreas transplantation from a separate donor

Transpl Int. 2014 Jul;27(7):e58-62. doi: 10.1111/tri.12308. Epub 2014 Apr 10.

Abstract

Whole-organ pancreas transplantation is typically carried out using a Y-graft derived from the donor iliac vessels. We describe a case in which a 31-year-old male underwent a simultaneous pancreas-kidney transplant, but in which vessels from a different donor were used for the arterial anastomosis of the pancreas graft. Although initially there was good function, 18 months post-transplant the patient was admitted with diabetic ketoacidosis secondary to pancreas graft failure. Radiological investigations revealed complete occlusion of the vascular Y-graft, and laboratory investigations demonstrated donor-specific human leucocyte antigen (HLA) antibodies directed against HLA mismatches of the vessel donor. This case highlights the risks of using allogeneic vascular material for surgical anastomoses.

Keywords: donor-specific antibodies; pancreas transplant.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Anastomosis, Surgical / adverse effects*
  • Antibodies / immunology
  • Graft Rejection / immunology
  • Humans
  • Kidney Transplantation*
  • Male
  • Pancreas Transplantation*
  • Tissue Donors

Substances

  • Antibodies