Comparison of transfemoral transcatheter aortic valve replacement performed in the catheterization laboratory (minimalist approach) versus hybrid operating room (standard approach): outcomes and cost analysis

JACC Cardiovasc Interv. 2014 Aug;7(8):898-904. doi: 10.1016/j.jcin.2014.04.005. Epub 2014 Jul 30.

Abstract

Objectives: The aim of this study was to compare transfemoral transcatheter aortic valve replacement (TF TAVR) performed in a catheterization laboratory (minimalist approach [MA]) with TF TAVR performed in a hybrid operating room (standard approach [SA]).

Background: A MA-TF TAVR can be performed without general anesthesia, transesophageal echocardiography, or a surgical hybrid room. The outcomes and cost of MA-TF TAVR compared with those of the SA have not been described.

Methods: Patients who underwent elective, percutaneous TF TAVR using the Edwards Sapien valve (Edwards Lifesciences, Irvine, California) were studied. Baseline characteristics, outcomes, and hospital costs of MA-TF TAVR and SA-TF TAVR were compared.

Results: A total of 142 patients were studied (MA-TF TAVR, n = 70 and SA-TF TAVR, n = 72). There were no differences in baseline comorbidities (Society of Thoracic Surgeons score, 10.6 ± 4.3 vs. 11.4 ± 5.8; p = 0.35). All procedures in the MA-TF TAVR group were successful; 1 patient was intubated. Three patients in the SA-TF TAVR group had procedure-related death. Procedure room time (150 ± 48 min vs. 218 ± 56 min, p < 0.001), total intensive care unit time (22 h vs. 28 h, p < 0.001), length of stay from procedure to discharge (3 days vs. 5 days, p < 0.001), and cost ($45,485 ± 14,397 vs. $55,377 ± 22,587, p < 0.001) were significantly less in the MA-TF TAVR group. Mortality at 30 days was not significantly different in the MA-TF TAVR group (0 vs. 6%, p = 0.12) and 30-day stroke/transient ischemic attack was similar (4.3% vs. 1.4%, p = 0.35). Moderate or severe paravalvular leak and device success were similar in the MA-TF TAVR and SA-TF TAVR groups (3% vs. 5.8%, p = 0.4 and 90% vs. 88%, p = 0.79, respectively) at 30 days. At a median follow-up of 435 days, there was no significant difference in survival (MA-TF TAVR, 83% vs. SA-TF TAVR, 82%; p = 0.639).

Conclusions: MA-TF TAVR can be performed with minimal morbidity and mortality and equivalent effectiveness compared with SA-TF TAVR. The shorter length of stay and lower resource use with MA-TF TAVR significantly lowers hospital costs.

Keywords: TAVI; TAVR; aortic stenosis; cost; minimalist; transcatheter aortic valve replacement.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Anesthesia, General / economics
  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / economics*
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / therapy*
  • Cardiac Catheterization / economics*
  • Cardiac Catheterization / instrumentation
  • Cardiac Catheterization / methods
  • Cardiac Catheterization / mortality
  • Cost Savings
  • Cost-Benefit Analysis
  • Echocardiography, Transesophageal / economics
  • Female
  • Femoral Artery*
  • Georgia
  • Heart Valve Prosthesis / economics
  • Heart Valve Prosthesis Implantation / economics*
  • Heart Valve Prosthesis Implantation / instrumentation
  • Heart Valve Prosthesis Implantation / methods
  • Heart Valve Prosthesis Implantation / mortality
  • Hospital Costs*
  • Humans
  • Intensive Care Units / economics
  • Length of Stay / economics
  • Male
  • Operating Rooms / economics*
  • Process Assessment, Health Care / economics*
  • Prosthesis Design
  • Retrospective Studies
  • Risk Factors
  • Time Factors
  • Treatment Outcome