Mandated self-reporting of ventilator-associated pneumonia bundle and catheter-related bloodstream infection bundle compliance and infection rates

JAMA Surg. 2014 Oct;149(10):1003-7. doi: 10.1001/jamasurg.2014.1627.

Abstract

Importance: As quality measures increasingly become tied to payment, evaluating the most effective ways to provide high-quality care becomes more important.

Objectives: To determine whether mandated reporting for ventilator and catheter bundle compliance is correlated with decreased infection rates, and to determine whether labor-intensive audits are correlated with compliance.

Design, setting, and participants: Multiyear retrospective review of aggregated data from all patients admitted to 15 intensive care units in a Veterans Affairs hospital setting (the Veterans Integrated Service Network 16) from 2009 to 2011.

Exposures: Ventilator-associated pneumonia and catheter-related bloodstream infections.

Main outcomes and measures: Mean rates of ventilator-associated pneumonia and catheter-related bloodstream infection were analyzed by year. Relationships between infection rates, self-reported compliance, and audits were analyzed by Pearson correlation.

Results: During the study period, ventilator-associated pneumonia decreased from 2.50 to 1.60 infections per 1000 ventilator days (P = .07). The rate of pneumonia was not correlated with self-reported compliance overall (R = 0.19) or by individual year (2009, R = 0.30; 2010, R = 0.24; 2011, R = 0.46); there was a correlation in cardiac intensive care units (R = -0.70) but not other types of intensive care units (mixed, R = -0.18; medical, R = 0.42; surgical, R = 0.34). Catheter-related bloodstream infections decreased from 2.38 to 0.73 infections per 1000 catheter days (P = .04). The rate of catheter infection was not correlated with self-reported compliance overall (R = -0.18), by individual year (2009, R = -0.39; 2010, R = -0.42; 2011, R = 0.37), or by intensive care unit type (mixed, R = -0.19; cardiac, R = 0.55; medical, R = 0.17; surgical, R = -0.44).

Conclusions and relevance: Current mandated self-reported compliance and audit measures are poorly correlated with decreased ventilator-associated pneumonia or catheter-related bloodstream infection.

Publication types

  • Multicenter Study

MeSH terms

  • Bacteremia / epidemiology*
  • Bacteremia / prevention & control*
  • Catheter-Related Infections / epidemiology*
  • Catheter-Related Infections / prevention & control*
  • Cross Infection / epidemiology*
  • Cross Infection / prevention & control*
  • Hospitals, Veterans
  • Humans
  • Infection Control / methods
  • Mandatory Reporting*
  • Pneumonia, Ventilator-Associated / epidemiology*
  • Pneumonia, Ventilator-Associated / prevention & control*
  • Retrospective Studies
  • United States / epidemiology