Background: Early recognition and timely intervention significantly reduce sepsis-related mortality.
Objective: Describe the development, implementation, and impact of an early warning and response system (EWRS) for sepsis.
Design: After tool derivation and validation, a preimplementation/postimplementation study with multivariable adjustment measured impact.
Setting: Urban academic healthcare system.
Patients: Adult non-ICU patients admitted to acute inpatient units from October 1, 2011 to October 31, 2011 for tool derivation, June 6, 2012 to July 5, 2012 for tool validation, and June 6, 2012 to September 4, 2012 and June 6, 2013 to September 4, 2013 for the preimplementation/postimplementation analysis.
Intervention: An EWRS in our electronic health record monitored laboratory values and vital signs in real time. If a patient had ≥4 predefined abnormalities at any single time, the provider, nurse, and rapid response coordinator were notified and performed an immediate bedside patient evaluation.
Measurements: Screen positive rates, test characteristics, predictive values, and likelihood ratios; system utilization; and resulting changes in processes and outcomes.
Results: The tool's screen positive, sensitivity, specificity, and positive and negative predictive values and likelihood ratios for our composite of intensive care unit (ICU) transfer, rapid response team call, or death in the derivation cohort was 6%, 16%, 97%, 26%, 94%, 5.3, and 0.9, respectively. Validation values were similar. The EWRS resulted in a statistically significant increase in early sepsis care, ICU transfer, and sepsis documentation, and decreased sepsis mortality and increased discharge to home, although neither of these latter 2 findings reached statistical significance.
Conclusions: An automated prediction tool identified at-risk patients and prompted a bedside evaluation resulting in more timely sepsis care, improved documentation, and a suggestion of reduced mortality.