Purpose: To evaluate the clinical feasibility and diagnostic accuracy of three-dimensional (3D) quantitative magnetic resonance (MR) imaging for the assessment of total lesion volume (TLV) and enhancing lesion volume (ELV) before and after uterine artery embolization (UAE).
Materials and methods: This retrospective study included 25 patients with uterine fibroids who underwent UAE and received contrast-enhanced MR imaging before and after the procedure. TLV was calculated using a semiautomated 3D segmentation of the dominant lesion on contrast-enhanced MR imaging, and ELV was defined as voxels within TLV where the enhancement exceeded the value of a region of interest placed in hypoenhancing soft tissue (left psoas muscle). ELV was expressed in relative (% of TLV) and absolute (in cm(3)) metrics. Results were compared with manual measurements and correlated with symptomatic outcome using a linear regression model.
Results: Although 3D quantitative measurements of TLV demonstrated a strong correlation with the manual technique (R(2) = 0.93), measurements of ELV after UAE showed significant disagreement between techniques (R(2) = 0.72; residual standard error, 15.8). Six patients (24%) remained symptomatic and were classified as nonresponders. When stratified according to response, no difference in % ELV between responders and nonresponders was observed. When assessed using cm(3) ELV, responders showed a significantly lower mean ELV compared with nonresponders (4.1 cm(3) [range, 0.3-19.8 cm(3)] vs 77 cm(3) [range, 11.91-296 cm(3)]; P < .01).
Conclusions: The use of segmentation-based 3D quantification of lesion enhancement is feasible and diagnostically accurate and could be considered as an MR imaging response marker for clinical outcome after UAE.
Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.