Handheld echocardiographic screening for rheumatic heart disease by non-experts

Heart. 2016 Jan;102(1):35-9. doi: 10.1136/heartjnl-2015-308236. Epub 2015 Oct 5.

Abstract

Objectives: Handheld echocardiography (HAND) has good sensitivity and specificity for rheumatic heart disease (RHD) when performed by cardiologists. However, physician shortages in RHD-endemic areas demand less-skilled users to make RHD screening practical. We examine nurse performance and interpretation of HAND using a simplified approach for RHD screening.

Methods: Two nurses received training on HAND and a simplified screening approach. Consented students at two schools in Uganda were eligible for participation. A simplified approach (HAND performed and interpreted by a non-expert) was compared with the reference standard (standard portable echocardiography, performed and interpreted by experts according to the 2012 World Heart Federation guidelines). Reasons for false-positive and false-negative HAND studies were identified.

Results: A total of 1002 children were consented, with 956 (11.1 years, 41.8% male) having complete data for review. Diagnoses included: 913 (95.5%) children were classified normal, 32 (3.3%) borderline RHD and 11 (1.2%) definite RHD. The simplified approach had a sensitivity of 74.4% (58.8% to 86.5%) and a specificity of 78.8% (76.0% to 81.4%) for any RHD (borderline and definite). Sensitivity improved to 90.9% (58.7% to 98.5%) for definite RHD. Identification and measurement of erroneous colour jets was the most common reason for false-positive studies (n=164/194), while missed mitral regurgitation and shorter regurgitant jet lengths with HAND were the most common reasons for false-negative studies (n=10/11).

Conclusions: Non-expert-led HAND screening programmes offer a potential solution to financial and workforce barriers that limit widespread RHD screening. Nurses trained on HAND using a simplified approach had reasonable sensitivity and specificity for RHD screening. Information on reasons for false-negative and false-positive screening studies should be used to inform future training protocols, which could lead to improved screening performance.

Publication types

  • Evaluation Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Aortic Valve / diagnostic imaging
  • Aortic Valve / physiopathology
  • Child
  • Clinical Competence
  • Developing Countries
  • Echocardiography, Doppler, Color / instrumentation
  • Echocardiography, Doppler, Color / nursing*
  • False Negative Reactions
  • False Positive Reactions
  • Female
  • Heart Valve Diseases / diagnostic imaging*
  • Heart Valve Diseases / nursing*
  • Heart Valve Diseases / physiopathology
  • Humans
  • Male
  • Mitral Valve / diagnostic imaging
  • Mitral Valve / physiopathology
  • Observer Variation
  • Point-of-Care Systems*
  • Point-of-Care Testing*
  • Predictive Value of Tests
  • Prognosis
  • Prospective Studies
  • Reproducibility of Results
  • Rheumatic Heart Disease / diagnostic imaging*
  • Rheumatic Heart Disease / nursing*
  • Rheumatic Heart Disease / physiopathology
  • Task Performance and Analysis
  • Uganda