Safety and Efficacy of Everolimus- Versus Sirolimus-Eluting Stents: 5-Year Results From SORT OUT IV

J Am Coll Cardiol. 2016 Feb 23;67(7):751-62. doi: 10.1016/j.jacc.2015.11.051.

Abstract

Background: Long-term safety and efficacy for everolimus-eluting stents (EES) versus those of sirolimus-eluting stents (SES) are unknown.

Objectives: This study compared 5-year outcomes for EES with those for SES from the SORT OUT IV (Scandinavian Organization for Randomized Trials with Clinical Outcome) trial.

Methods: Five-year follow-up was completed for 2,771 patients (99.9%). Primary endpoint was a composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), target vessel revascularization (TVR), and definite stent thrombosis.

Results: At 5-years, MACE occurred in 14.0% and 17.4% in the EES and SES groups, respectively (hazard ratio [HR]: 0.80, 95% confidence interval [CI]: 0.66 to 0.97; p = 0.02). The MACE rate did not differ significantly within the first year (HR: 0.96, 95% CI: 0.71 to 1.19; p = 0.79), but from years 1 through 5, the MACE rate was lower with EES (HR: 0.71, 95% CI: 0.55 to 0.90; p = 0.006; p interaction = 0.12). Definite stent thrombosis was lower with EES (0.4%) than with SES (2.0%; HR: 0.18, 95% CI: 0.07 to 0.46), with a lower risk of very late definite stent thrombosis in the EES group (0.2% vs. 1.4%, respectively; HR: 0.16, 95% CI: 0.05 to 0.53). When censoring the patients at the time of stent thrombosis, we found no significant differences between the 2 stent groups for MACE rates (HR: 0.89, 95% CI: 0.73 to 1.08; p = 0.23), target lesion revascularization (HR: 0.90, 95% CI: 0.64 to 1.27; p = 0.55), and MI (HR: 0.93, 95% CI: 0.64 to 1.36; p = 0.72).

Conclusions: At 5-year follow-up, MACE rate was significantly lower with EES- than with SES-treated patients, due largely due to a lower risk of very late definite stent thrombosis. (Randomized Clinical Comparison of the Xience V and the Cypher Coronary Stents in Non-selected Patients With Coronary Heart Disease [SORT OUT IV]; NCT00552877).

Keywords: drug-eluting stent(s); outcome; percutaneous coronary intervention; very late definite stent thrombosis.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Coronary Artery Disease / surgery*
  • Denmark / epidemiology
  • Drug-Eluting Stents*
  • Everolimus / pharmacology*
  • Female
  • Follow-Up Studies
  • Humans
  • Immunosuppressive Agents / pharmacology
  • Incidence
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Percutaneous Coronary Intervention / methods*
  • Postoperative Complications / epidemiology
  • Prosthesis Design
  • Retrospective Studies
  • Single-Blind Method
  • Sirolimus / pharmacology*
  • Survival Rate / trends
  • Time Factors
  • Treatment Outcome

Substances

  • Immunosuppressive Agents
  • Everolimus
  • Sirolimus

Associated data

  • ClinicalTrials.gov/NCT00552877