Nickel is the most frequent allergen in patients with allergic contact dermatitis and nickel allergy has been associated with recurrent in-stent restenosis. However, it is often misdiagnosed because of a low suspicion threshold. It should be discarded in patients with recurrent in-stent restenosis, especially if their medical history reveals prior contact dermatitis. It is also noteworthy and rarely specified that even newer generation stents that use novel metal alloys also contain low amounts of nickel. To avoid the implantation of new stents containing this metal, when percutaneous coronary intervention is indicated, drug eluting balloons or bioresorbable vascular scaffolds associated with small doses of steroids could provide good alternatives of treatment. To the best of our knowledge, this is the first description of this therapeutic alternative in such an exceedingly rare clinical scenario.
Keywords: Bioresorbable vascular scaffold; Nickel allergy; Restenosis.