Construction of the intestinal stoma with an intraluminal stapling device

J Urol. 1989 Nov;142(5):1279-81. doi: 10.1016/s0022-5347(17)39056-0.

Abstract

We have used the intraluminal circular stapler to facilitate construction of the intestinal conduit stoma. We have encountered no complications related to the stapled stoma construction technique in 8 patients. The stoma is circular, uniform in size and is fitted easily with an appliance. The circular staple line provides a watertight seal that prevents contamination of the subcutaneous tissues. The technique is rapid, reliable and reproducible.

MeSH terms

  • Colostomy / instrumentation
  • Colostomy / methods*
  • Humans
  • Ileostomy / instrumentation
  • Ileostomy / methods*
  • Surgical Staplers*
  • Urinary Diversion / instrumentation
  • Urinary Diversion / methods*