Prolapse of the Pipeline embolization device in aneurysms: incidence, management, and outcomes

Neurosurg Focus. 2017 Jun;42(6):E16. doi: 10.3171/2017.3.FOCUS1738.

Abstract

OBJECTIVE The Pipeline embolization device (PED) is frequently used in the treatment of anterior circulation aneurysms, especially around the carotid siphon, with generally excellent results. However, the PED has its own unique technical challenges, including the occurrence of device foreshortening or migration leading to prolapse into the aneurysm. The authors sought to determine the incidence of this phenomenon, the rescue strategies, and outcomes. METHODS Four institutional databases of neuroendovascular procedures were reviewed for cases of intracranial aneurysms treated with PEDs. Patient and aneurysm data as well as angiographic imaging were reviewed for all cases involving device prolapse into the aneurysm. RESULTS A total of 413 intracranial aneurysms were treated with PEDs during the study period, by 5 neurointerventionalists. Large and giant aneurysms (≥ 2 cm) accounted for 32 of these aneurysms. Among these 32 PEDs, prolapse into the aneurysm occurred in 3 patients, with 1 of these PEDs successfully rescued and the other 2 left in situ. No patients suffered any severe complications. The 2 patients in whom the PEDs were left in situ remained on antiplatelet therapy. CONCLUSIONS The PED may foreshorten or migrate during or after deployment, leading to prolapse into the aneurysm. This phenomenon appears to be associated with large and giant aneurysms, vessel tortuosity, short landing zones, and use of balloon angioplasty. Future study and follow-up is needed to further evaluate this phenomenon, but some of the observations and techniques described in this paper may help to prevent or salvage prolapsed devices.

Keywords: BTO = balloon test occlusion; CTA = CT angiography; ICA = internal carotid artery; PCoA = posterior communicating artery; PED = Pipeline embolization device; PTA = percutaneous transluminal angioplasty; Pipeline embolization device; aneurysm; flow diversion; foreshortening; migration; prolapse.

Publication types

  • Case Reports
  • Multicenter Study

MeSH terms

  • Aged, 80 and over
  • Cerebral Angiography
  • Disease Management*
  • Embolization, Therapeutic / instrumentation
  • Embolization, Therapeutic / methods*
  • Female
  • Humans
  • Incidence
  • Intracranial Aneurysm* / diagnosis
  • Intracranial Aneurysm* / epidemiology
  • Intracranial Aneurysm* / therapy
  • Male
  • Middle Aged
  • Prolapse
  • Retrospective Studies