Background: Repeated implantable cardioverter-defibrillator (ICD) therapies cause myocardial damage and, thus, an increased risk of arrhythmias and mortality.
Hypothesis: Cardiac resynchronization therapy-defibrillator (CRT-D) reduces the number of appropriate therapies in patients with left ventricular dysfunction (left ventricular ejection fraction [LVEF] <50%).
Methods: The retrospective study involved 175 consecutive patients (mean age, 64.6 ±10.4 years; 86.9% males) with reduced LVEF of 27.9% ±7.6% treated with an ICD (56.6%) or CRT-D (43.4%), according to standard indications, between January 2009 and July 2014. Devices were placed for either primary (54.3%) or secondary prevention (45.7%). Mean follow-up was 2.5 ±1.5 years. Predictors of first appropriate therapy were assessed using Cox regression analysis.
Results: Forty-four (25.1%) patients received ≥1 appropriate therapy. Although patients treated with CRT-D had lower LVEF and poorer New York Heart Association class, CRT-D patients with LVEF improvement >35% at the end of follow-up had a significantly lower risk of receiving a first appropriate therapy relative to those with an ICD (adjusted hazard ratio: 0.24, 95% confidence interval: 0.07-0.83, P = 0.025), independently of ischemic cardiomyopathy, baseline LVEF, and secondary prevention. There were no differences in mortality between the ICD and the CRT-D groups.
Conclusions: Although patients receiving CRT-D had a worse clinical profile, they received fewer device therapies in comparison with those receiving an ICD. This reduction is associated with a significant improvement in LVEF.
Keywords: Cardiac Resynchronization Therapy; Heart Failure; ICD Therapy.
© 2018 Wiley Periodicals, Inc.