Arrhythmic Burden as Determined by Ambulatory Continuous Cardiac Monitoring in Patients With New-Onset Persistent Left Bundle Branch Block Following Transcatheter Aortic Valve Replacement: The MARE Study

JACC Cardiovasc Interv. 2018 Aug 13;11(15):1495-1505. doi: 10.1016/j.jcin.2018.04.016. Epub 2018 Jul 18.

Abstract

Objectives: The authors sought to determine: 1) the global arrhythmic burden; 2) the rate of arrhythmias leading to a treatment change; and 3) the incidence of high-degree atrioventricular block (HAVB) at 12-month follow-up in patients with new-onset persistent left bundle branch block (LBBB) following transcatheter aortic valve replacement (TAVR).

Background: Controversial data exist on the occurrence of significant arrhythmias in patients with LBBB post-TAVR.

Methods: This was a multicenter prospective study including 103 consecutive patients with new-onset persistent LBBB post-TAVR with the balloon-expandable SAPIEN XT/3 valve (n = 53), or the self-expanding CoreValve/Evolut R system (n = 50). An implantable cardiac monitor (Reveal XT, Reveal Linq) was implanted at 4 (3 to 6) days post-TAVR, and patients had continuous electrocardiogram monitoring for 12 months. All arrhythmic events were adjudicated in a central electrocardiography core lab. Primary endpoints were the incidence of arrhythmias leading to a treatment change, and the incidence of HAVB at 12-month follow-up.

Results: A total of 1,553 new arrhythmic events were detected in 44 patients (1,443 episodes of tachyarrhythmia in 26 patients [atrial fibrillation/flutter/atrial tachycardia: 1,427, ventricular tachycardia 16]; 110 episodes of bradyarrhythmia in 21 patients [HAVB 54, severe bradycardia 56]). All arrhythmic events were silent in 34 patients (77%), the arrhythmic event led to a treatment change in 19 patients (18%), and 11 patients (11%) required pacemaker or implantable cardioverter-defibrillator implantation (due to HAVB, severe bradycardia, or ventricular tachycardia episodes in 9, 1, and 1 patient, respectively). A total of 12 patients died at 1-year follow-up, 1 from sudden death.

Conclusions: A high incidence of arrhythmic events was observed at 1-year follow-up in close to one-half of the patients with LBBB post-TAVR. Significant bradyarrhythmias occurred in one-fifth of the patients, and PPM was required in nearly one-half of them. These data support the use of a cardiac monitoring device for close follow-up and expediting the initiation of treatment in this challenging group of patients. (Ambulatory Electrocardiographic Monitoring for the Detection of High-Degree Atrio-Ventricular Block in Patients With New-onset PeRsistent LEft Bundle Branch Block After Transcatheter Aortic Valve Implantation [MARE study]: NCT02153307).

Keywords: atrial fibrillation; bradyarrhythmias; left bundle branch block; pacemaker implantation; transcatheter aortic valve replacement.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Action Potentials
  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis / epidemiology
  • Aortic Valve Stenosis / surgery*
  • Arrhythmias, Cardiac / diagnosis*
  • Arrhythmias, Cardiac / epidemiology
  • Arrhythmias, Cardiac / physiopathology
  • Arrhythmias, Cardiac / therapy
  • Bundle-Branch Block / diagnosis*
  • Bundle-Branch Block / epidemiology
  • Bundle-Branch Block / physiopathology
  • Bundle-Branch Block / therapy
  • Canada / epidemiology
  • Electrocardiography, Ambulatory*
  • Europe / epidemiology
  • Female
  • Heart Rate
  • Humans
  • Incidence
  • Male
  • Predictive Value of Tests
  • Prospective Studies
  • Risk Factors
  • Time Factors
  • Transcatheter Aortic Valve Replacement / adverse effects*
  • Treatment Outcome
  • United States / epidemiology

Associated data

  • ClinicalTrials.gov/NCT02153307