Study design: Systematic literature review and meta-analysis.
Objective: The objective of this systematic literature review was to evaluate if intraoperative neurophysiological monitoring (IONM) can prevent neurological injury during spinal operative surgical procedures.
Summary of background data: IONM seems to have presumable positive effects in identifying neurological deficits. However, the role of IONM in the decrease of new neurological deficits remains unclear.
Methods: Using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for systematic reviews and Meta-analysis, we reviewed clinical comparative studies who evaluate the rate of new neurological events in patients who had a spinal surgery with and without IONM. Studies were then classified according to their level of evidence. Methodological quality was assessed according to methodological index for non-randomized studies instrument.
Results: Six studies were evaluated comparing neurological events with and without IONM use by the random effects model. There was a great statistical heterogeneity. The pooled odds ratio (OR) was 0.72 {0.71; 1.79}, P = 0.4584. A specific analysis was done for two studies reporting the results of IONM for spinal surgery of intramedullary lesions. The OR was 0.1993 (0.0384; 1.0350), P = 0.0550.
Conclusion: IONM did not result into fewer neurological events with the obtained evidence of the included studies. For intramedullary lesions, there was a trend to fewer neurological events in patients who underwent surgery with IONM. Further prospective randomized studies are necessary to clarify the indications of IONM in spinal surgeries.
Level of evidence: 2.