Noise insertion in CT for cocaine body packing: where is the limit of extensive dose reduction?

Eur J Med Res. 2018 Dec 7;23(1):59. doi: 10.1186/s40001-018-0356-3.

Abstract

Background: To evaluate the detection rate and image quality in CT-body-packer-screening at different radiation-dose levels and to determine a dose threshold that enables a reliable detection of incorporated body packs and incidental findings with a maximum of dose saving.

Materials and methods: We retrospectively included 27 individuals who underwent an abdominal CT with automated exposure control due to suspected body packing. CT images were reconstructed at different radiation-dose levels of 50%, 10, 5% and 1% using iterative reconstructions. All 135 CT reconstructions were evaluated by three independent readers. Reviewers determined the presence of foreign bodies and evaluated the image quality using a 5-point ranking scale. In addition, visualization of incidental findings was assessed.

Results: A threshold of 5% (effective dose 0.11 ± 0.07 mSv) was necessary to correctly identify all 27 patients with suspected body packing. Extensive noise insertion to a dose level of 1% (0.02 ± 0.01 mSV) led to false-positive solid cocaine findings in three patients. Image quality was comparable between 100 and 50%. The threshold for correct identification of incidental findings was 10% of the initial dose (effective dose 0.21 ± 0.13 mSv).

Conclusions: Our results indicate that dose of abdominal CT for the detection of intracorporeal cocaine body packets can be markedly reduced to up to 5% of the initial dose while still providing sufficient image quality to detect ingested body packets. However, a minimum effective dose of 0.21 mSv (10% of initial dose) seems to be required to properly identify incidental findings.

Keywords: CT dose; Drug abuse; Image analysis; Low dose CT.

MeSH terms

  • Adult
  • Body Packing*
  • Cocaine*
  • Female
  • Foreign Bodies / diagnostic imaging*
  • Humans
  • Male
  • Middle Aged
  • Radiation Dosage
  • Radiography, Abdominal / methods
  • Reproducibility of Results
  • Retrospective Studies
  • Tomography, X-Ray Computed / methods*
  • Young Adult

Substances

  • Cocaine