Assessing the efficacy, safety and utility of 6-month day-and-night automated closed-loop insulin delivery under free-living conditions compared with insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, multicentre, multinational, single-period, randomised, parallel group study protocol

BMJ Open. 2019 Jun 3;9(6):e027856. doi: 10.1136/bmjopen-2018-027856.

Abstract

Introduction: Closed-loop systems titrate insulin based on sensor glucose levels, providing novel means to reduce the risk of hypoglycaemia while improving glycaemic control. We will assess effectiveness of 6-month day-and-night closed-loop insulin delivery compared with usual care (conventional or sensor-augmented pump therapy) in children and adolescents with type 1 diabetes.

Methods and analysis: The trial adopts an open-label, multicentre, multinational (UK and USA), randomised, single-period, parallel design. Participants (n=130) are children and adolescents (aged ≥6 and <19 years) with type 1 diabetes for at least 1 year, and insulin pump use for at least 3 months with suboptimal glycaemic control (glycated haemoglobin ≥58 mmol/mol (7.5%) and ≤86 mmol/mol (10%)). After a 2-3 week run-in period, participants will be randomised to 6-month use of hybrid closed-loop insulin delivery, or to usual care. Analyses will be conducted on an intention-to-treat basis. The primary outcome is glycated haemoglobin at 6 months. Other key endpoints include time in the target glucose range (3.9-10 mmol/L, 70-180 mg/dL), mean sensor glucose and time spent above and below target. Secondary outcomes include SD and coefficient of variation of sensor glucose levels, time with sensor glucose levels <3.5 mmol/L (63 mg/dL) and <3.0 mmol/L (54 mg/dL), area under the curve of glucose <3.5 mmol/L (63 mg/dL), time with glucose levels >16.7 mmol/L (300 mg/dL), area under the curve of glucose >10.0 mmol/L (180 mg/dL), total, basal and bolus insulin dose, body mass index z-score and blood pressure. Cognitive, emotional and behavioural characteristics of participants and caregivers and their responses to the closed-loop and clinical trial will be assessed. An incremental cost-effectiveness ratio for closed-loop will be estimated.

Ethics and dissemination: Cambridge South Research Ethics Committee and Jaeb Center for Health Research Institutional Review Office approved the study. The findings will be disseminated by peer-review publications and conference presentations.

Trial registration number: NCT02925299; Pre-results.

Keywords: artificial pancreas; closed-loop; type 1 diabetes.

Publication types

  • Clinical Trial Protocol
  • Comparative Study
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Child
  • Diabetes Mellitus, Type 1 / drug therapy*
  • Humans
  • Hypoglycemic Agents / administration & dosage*
  • Hypoglycemic Agents / adverse effects
  • Insulin Infusion Systems
  • Insulins / administration & dosage*
  • Insulins / adverse effects
  • Multicenter Studies as Topic / methods
  • Pancreas, Artificial
  • Patient Safety
  • Randomized Controlled Trials as Topic / methods
  • Treatment Outcome

Substances

  • Hypoglycemic Agents
  • Insulins

Associated data

  • ClinicalTrials.gov/NCT02925299