Laboratory-based versus qualitative assessment of α-defensin in periprosthetic hip and knee infections: a systematic review and meta-analysis

Arch Orthop Trauma Surg. 2020 Mar;140(3):293-301. doi: 10.1007/s00402-019-03232-5. Epub 2019 Jul 12.

Abstract

Introduction: Two methods are currently available for the assay of α-defensin: the enzyme-linked immunosorbent assay (ELISA) and the lateral flow test. We aimed to assess the diagnostic accuracy of synovial fluid α-defensin and to compare the accuracy of the laboratory-based test and the qualitative assessment for the diagnosis of hip and knee prosthetic infection.

Materials and methods: We searched (from inception to May 2018) MEDLINE, Scopus, EMBASE, Web of Science, and Cochrane for studies on α-defensin in the diagnosis of periprosthetic joint infection (PJI). Sensitivity, specificity, positive and negative likelihood ratio (LR), and diagnostic odds ratio were analyzed using the bivariate diagnostic random-effects model. The receiver-operating curve for each method was calculated.

Results: We included 13 articles in our meta-analysis, including 1170 patients who underwent total hip and knee arthroplasties revision; 368 (31%) had a joint infection according to MSIS and MSIS-modified criteria. Considering the false-positive result rate of 8% and false-negative result rate of 3%, pooled sensitivity and specificity were 0.90 (95% CI 0.83-0.94) and 0.95 (0.92-0.96), respectively. The area under the curve (AUC) was 0.94 (0.92-0.94). No statistical differences in terms of sensitivity and specificity were found between the laboratory-based and qualitative test. The pooled sensitivity and specificity of the two alpha-defensin assessment methods were: laboratory-based test 0.97 (95% CI 0.93-0.99) and 0.96 (95% CI 0.94-0.98), respectively; qualitative test 0.83 (95% CI 0.73-0.91) and 0.94 (95% CI 0.89-0.97), respectively. The diagnostic odds ratio of the α-defensin laboratory based was superior to that of the qualitative test (1126.085, 95% CI 352.172-3600.702 versus 100.9, 95% CI 30.1-338.41; p < 0.001). The AUC for immunoassay and qualitative tests was 0.97 (0.95-0.99) and 0.91 (0.88-0.99), respectively.

Conclusion: Detection of α-defensin is an accurate test for diagnosis of hip and knee prosthetic infections. The diagnostic accuracy of the two alpha-defensin assessment methods is comparable. The lateral flow assay is a valid, rapid, and more available diagnostic tool, particularly to rule out PJI.

Keywords: Hip; Knee; Prosthetic joint infection; α-Defensin.

Publication types

  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Biomarkers / analysis
  • Hip Joint / chemistry
  • Hip Prosthesis / adverse effects*
  • Humans
  • Knee Joint / chemistry
  • Knee Prosthesis / adverse effects*
  • Prosthesis-Related Infections / diagnosis*
  • Sensitivity and Specificity
  • Synovial Fluid / chemistry*
  • alpha-Defensins / analysis*

Substances

  • Biomarkers
  • alpha-Defensins