This study was conducted to develop a highly selective, sensitive, and validated method for quantifying metronidazole in human plasma and bile fluid. Metronidazole and metronidazole-d4 (internal standard) were extracted from 100 μL of plasma and bile fluid by liquid-liquid extraction. Liquid chromatography with a Hydrosphere C18 column (50 × 2.0 mm) was performed using 10 mM ammonium formate (pH 4.0) and acetonitrile (20:80, v/v) as the mobile phase. Triple quadrupole mass spectrometry was operated with an electrospray ionization interface in multiple reaction monitoring and positive ion modes. The calibration curves were linear for bile and plasma samples over the range of 50-20,000 ng/mL (r2 > 0.999). The intra- and inter-day coefficients of variation (CVs) for plasma ranged from 2.50% to 7.85% and 3.11% to 16.9%, respectively; for bile, the intra-and inter-run precision (CVs) ranged from 2.76% to 13.2% and 3.16% to 11.5%, respectively. The mean extraction recovery for metronidazole ranged from 76.5% to 82.1% in plasma and from 78.8% to 87.8% in bile, respectively. Our proposed analytical method was successfully applied to determine metronidazole concentrations in bile as well as in plasma at multiple time points in a patient with acute cholangitis.
Copyright © 2019 Elsevier B.V. All rights reserved.