West Nile virus (WNV) and St. Louis encephalitis virus (SLEV) are closely related mosquito-borne flaviviruses that cause clinical disease ranging from febrile illness to encephalitis. The standard for serological diagnosis is immunoglobulin M (IgM) testing followed by confirmatory plaque reduction neutralization test (PRNT) to differentiate the infecting virus. However, the PRNT is time-consuming and requires manipulation of live virus. During concurrent WNV and SLEV outbreaks in Arizona in 2015, we assessed use of a diagnostic algorithm to simplify testing. It incorporated WNV and SLEV ratios based on positive-to-negative (P/N) values derived from the IgM antibody-capture enzyme-linked immunosorbent assay. We compared each sample's ratio-based result with the confirmed WNV or SLEV sample result indicated by PRNT or PCR testing. We analyzed data from 70 patients with 77 serum and cerebrospinal fluid samples, including 53 patients with confirmed WNV infection and 17 patients with confirmed SLEV infection. Both WNV and SLEV ratios had specificity ≥95%, indicating a high likelihood that each ratio was correctly identifying the infecting virus. The SLEV ratio sensitivity of 30% was much lower than the WNV ratio sensitivity of 91%, likely because of higher cross-reactivity of SLEV antibodies and generation of lower P/N values. The standard for serological diagnosis of WNV and SLEV infections remains IgM testing followed by PRNT. However, these results suggest the ratios could potentially be used as part of a diagnostic algorithm in outbreaks to substantially reduce the need for PRNTs.
Keywords: MAC-ELISA; St. Louis encephalitis virus; West Nile virus; flavivirus.