Impact of significant paravalvular leaks after transcatheter aortic valve implantation on anaemia and mortality

Heart. 2020 Aug 25:heartjnl-2020-316941. doi: 10.1136/heartjnl-2020-316941. Online ahead of print.

Abstract

Objective: The aim of this work is to assess the relationship between significant paravalvular leak (SPL) after transcatheter aortic valve implantation (TAVI) on anaemia and their impact on prognosis.

Methods: Observational analytic study developed at two university hospitals, including all consecutive patients who underwent TAVI during a 10-year period (2009 to 2018). A logistic regression model was created to determine independent predictors of anaemia at 3 months. Time to event outcomes were analysed with Cox regression. Median follow-up was 21.3±21.9 months.

Results: 788 patients were included. 5.3% had SPL. SPL was an independent predictor of anaemia 3 months after TAVI (OR: 8.31, 95% CI: 2.06 to 33.50). SPL and anaemia at 3 months were independently associated with long-term mortality (HR: 1.82, 95% CI: 1.16 to 2.85; HR: 2.07, 95% CI: 1.39 to 3.08).

Conclusion: SPL is an independent predictor of anaemia at 3 months after TAVI, a condition that doubles long-term mortality. Our findings could explain in part the worse prognosis of SPL after TAVI. Further pathophysiological studies are necessary to explain this association.

Keywords: endovascular procedures for aortic and vascular disease.